So, I have a transformer that has two primary windings that can be typically be hooked up in parallel for 115 VAC operation or in series for 230 VAC operation as well as a couple of identical secondary windings. It looks something like this:
Let's take the scenario where we hook up only one primary to the mains. My thinking is that I can treat the second primary winding as another "secondary" and should see the mains voltage on this winding and it would therefore act like an isolation transformer as well as a step down transformer for the secondary voltages.
Where I am confused is the following scenario. Let's say we hook the mains to 1 and 2 above and use 3 and 4 as the input voltage to a full wave bridge rectifier, filter and regulator for my B+ supply. The B+ only needs about 100 ma current capability.
So, what if the transformer is rated at 50 VA and we are drawing sufficient current from the combined secondaries to equal 48 VA including the current drawn from the second primary winding. This is obviously less than the 50 VA rating of the transformer. But, in this case does the manufacturer expect that the primaries will be always wired in parallel and actually used as primaries? Do I risk drawing too much current through the single primary wired to the mains in this scenario? Anyone have any ideas? Is it likely that each winding can handle the maximum rated VA?
If I understand this correctly, if the transformer is rated at 50VA, then each winding must handle the equivalent current (voltages chosed to make the math easy):
50VA
------ = .5 A primary current total or .25 A each winding
100V
50VA
------ = 2 A secondary current total or 1 A each winding.
25V
So, if I have this correct, I risk over-heating the single primary hooked to mains if I am running at close to the rated VA of the transformer unless the manufacturer over-engineered the windings wire size. It seems I should limit the total secondary current to 1/2 the VA rating of the transformer if only a single primary is hooked to mains.
Thoughts? Am I thinking about this correctly?
Showing posts with label Power Supply. Show all posts
Showing posts with label Power Supply. Show all posts
Sunday, October 30, 2011
Tuesday, September 13, 2011
Powering up the SW-3 (again)
After discussing with my buddy Eldon, I have decided not to use the voltage divider approach to power the filaments. They are all wired in parallel and the risk from one of them opening up and thereby taking out the entire set of tubes is too great, not to mention the royal pain in the tush finding a 1.15 ohm 15 watt resistor will be. I decided to order a 2.5 volt 6 amp transformer from Mouser for $13 today and will use it to power the tubes. The other option would have been to rewire them all in series and use a voltage divider to come up with 7.5 volts from a 12 volt source. At least if a filament opens up we power everything down, plus the voltage divider would be easier to construct without having to locate 15 watt resistors.
I love a few select old pieces of equipment, but powering them can be a pain in the empennage. I have a couple sources for the B+ 135 volt supply, so we should be good to go once the transformer arrives.
Meanwhile, I am on the lookout for an old National "doghouse" power supply for the SW-3.
I love a few select old pieces of equipment, but powering them can be a pain in the empennage. I have a couple sources for the B+ 135 volt supply, so we should be good to go once the transformer arrives.
Meanwhile, I am on the lookout for an old National "doghouse" power supply for the SW-3.
Subscribe to:
Posts (Atom)